These cables have a wide range of applications, primarily used in power transmission and distribution scenarios with rated voltages of 1 kV and below. Common usage areas include powering industrial equipment within factories and workshops, providing electricity to residential complexes and commercial buildings via their distribution systems, supplying power for urban street lighting, park and landscape lighting, and municipal infrastructure projects. They are also ideal for rural irrigation systems and the distribution networks serving densely populated rural residential areas.

Category:

Power cable

These cables have a wide range of applications, primarily used in power transmission and distribution scenarios with rated voltages of 1 kV and below. Common applications include powering industrial equipment within factories and workshops, supplying electricity to residential complexes and commercial buildings via their distribution systems, providing power for urban street lighting, park and landscape lighting, and municipal infrastructure projects. They are also ideal for rural irrigation systems and the distribution networks serving densely populated areas where rural residents live collectively.

It is characterized by insulation and jacket designs tailored to various environments (such as underground, conduit installations, and indoor/outdoor applications), ensuring the safe and stable operation of low-voltage distribution systems.

 

Product Execution Standard

This product is manufactured in accordance with the GB/T 12706.1 standard, "Power cables with extruded insulation and their accessories — Rated voltages from 1 kV (Um = 1.2 kV) to 35 kV (Um = 40.5 kV) — Part 1: Cables rated at 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV)." 
We can manufacture according to standards such as IEC, IS, AS/NZS, JIS, BS, ASTM, DIN, and more—and we also accommodate customers' specific requirements.

 

Using features

1. The maximum long-term permissible operating temperature for the cable conductor is 70°C;

2. During a short circuit (with a maximum duration of no more than 5 seconds), the highest temperature of the cable conductor shall not exceed 140°C;

3. The ambient temperature during cable laying should not be lower than 0°C. Refer to the table below for the minimum bending radius of the cable during installation.

 

Project

Single-core cable

Multi-core cable

Non-armored

Armored

Non-armored

Armored

Minimum cable bending radius during installation

20D

15D

15D

12D

Minimum bending radius for cables near junction boxes and terminals (but ensure careful control of bending, e.g., by using a shaped guide plate)

15D

12D

12D

10D

Note: D represents the cable's outer diameter.    

 

Product Model and Name

Model Number

Name

V(L)V

Polyvinyl chloride insulated polyvinyl chloride sheathed power cable

V(L)Y

Polyvinyl chloride-insulated polyethylene-sheathed power cable

V(L)V22

PVC-insulated steel-tape armored PVC-sheathed power cable

V(L)V23

Polyvinyl chloride insulated steel tape armored polyethylene sheathed power cable

V(L)V32

PVC-insulated fine steel wire-armored PVC-sheathed power cable

V(L)V33

PVC-insulated, fine steel wire-armored, polyethylene-sheathed power cable

V(L)V62

PVC-insulated, non-magnetic metal-tape armored, PVC-sheathed power cable

V(L)V72

PVC-insulated, non-magnetic metallic wire-armored, PVC-sheathed power cable

Note: In addition to the above-mentioned models of PVC-sheathed power cables, our company also manufactures flame-retardant, fire-resistant, and termite-proof power cables. For flame-retardant power cables, simply add "ZA-", "ZB-", or "ZC-" before the model number; for fire-resistant cables, prefix the model number with "N-"; and for termite-proof cables, append "-FY" to the end of the model number.

 

Structural weight

Single-core armored cable structural weight

Cable 
Model

Core count x cross-section 
mm²

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Stainless steel 
Aluminum-alloy 
Armored

Metal wire 
Armored

Stainless steel 
Armored

Aluminum tape armor 
Pack

Metal wire 
Armored

Stainless Steel Strip Armored

Aluminum tape armor

Metal wire armor

Non-armored

W62

VLV62

W62

VLV62

W72

VLV72

W

VLV

W62
VLV62
W72
VLV72

1x10

1.4

1.8

1.8

12.9

14.1

14.8

304

242

309

247

306

245

160

99

1x16

1.4

1.8

1.8

13.9

15.1

15.8

380

283

384

287

381

284

223

126

1x25

1.4

1.8

1.8

15.2

16.4

17.1

486

331

489

335

497

343

324

169

1x35

1.4

1.8

1.8

16.2

17.4

18.1

592

383

595

386

603

394

418

208

1x50

1.4

1.8

1.8

18.0

19.2

20.8

756

475

757

476

818

537

558

277

1x70

1.4

1.8

1.8

19.6

20.8

22.4

988

568

987

568

1055

636

770

350

1x95

1.5

1.8

1.8

21.5

22.7

24.3

1273

694

1271

692

1344

764

1039

460

1x120

1.5

1.8

1.8

23.0

24.2

26.5

1531

800

1527

796

1663

932

1278

547

1x150

1.6

1.8

1.8

24.9

26.1

28.4

1843

942

1838

938

1982

1081

1578

677

1x185

1.7

1.8

1.8

27.1

28.3

30.6

2247

1110

2240

1103

2395

1259

1967

830

1x240

1.8

1.9

1.9

29.6

31.0

33.3

2823

1343

2829

1348

3001

1521

2527

1047

1x300

1.9

1.9

2.0

32.2

33.4

36.7

3469

1605

3458

1595

3747

1884

3145

1282

1x400

2.0

2.1

2.1

35.8

37.2

40.7

4384

2012

4388

2016

4731

2359

4022

1650

1x500

2.1

2.2

2.2

41.0

41.0

44.5

5873

2824

5487

2438

5862

2812

5081

2032

1x630

2.2

2.3

2.4

44.7

44.7

48.4

7265

3351

6841

2926

7270

3356

6396

2482

Note: Single-core metal-armored cables require magnetic shielding measures and are intended solely for DC power transmission systems.

 

Weight of the two-core cable structure

Cable 
Model

Number of cores × Cross-section 
mm2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

2 × 1.5

1.8

1.8

1.8

11.5

14.7

16.6

146

280

393

2 × 2.5

1.8

1.8

1.8

12.3

15.5

17.4

176

146

319

289

438

408

2×4

1.8

1.8

1.8

13.9

17.1

19

235

187

396

348

525

477

2 × 6

1.8

1.8

1.8

15.1

18.3

21.1

295

220

469

394

748

673

2 × 10

1.8

1.8

1.8

17.7

20.9

23.7

418

294

620

496

941

817

2 × 16

1.8

1.8

1.8

19.7

22.9

25.7

564

369

788

592

1145

949

2 × 25

1.8

1.8

1.8

22.3

25.5

29

797

486

1048

738

1601

1291

2 × 35

1.8

1.8

1.8

24.3

27.5

31

1010

588

1284

862

1888

1466

2 × 50

1.8

1.8

1.9

27.9

31.1

34.8

1348

782

1660

1095

2365

1799

2 × 70

1.9

1.9

2

26.7

29.9

34.4

1634

791

1933

1090

2817

1973

2 × 95

2

2.1

2.2

30.3

33.7

38.6

2198

1032

2551

1385

3572

2406

2 × 120

2.1

2.2

2.3

32.5

37.1

40.8

2696

1225

3406

1935

4160

2689

2 × 150

2.2

2.3

2.4

35.7

40.3

45

3311

1499

4087

2275

5285

3473

2 × 185

2.4

2.4

2.6

38.7

43.1

48.4

4105

1818

4920

2633

6258

3971

2 × 240

2.5

2.6

2.8

43.3

49.1

53.2

5264

2286

6314

3336

7709

4731

2 × 300

2.7

2.8

2.9

57.7

63.5

67.8

7272

3523

8655

4906

10528

6779

2 × 400

2.9

3.1

3.2

64.9

70.9

75.2

9287

4514

10867

6095

12953

8181

 

Three-core cable structure weight

Cable 
Model

Number of cores × Cross-section 
mm2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

3 × 1.5

1.8 

1.8 

1.8 

12.0 

15.2 

17.1 

170 

310 

424

3 × 2.5

1.8 

1.8 

1.8 

12.8 

16.0 

17.9 

209 

164 

358 

312 

479

433

3 × 4

1.8 

1.8 

1.8 

14.6 

17.8 

20.6 

288 

216 

457 

384 

730

657

3 × 6

1.8 

1.8 

1.8 

15.9 

19.1 

21.9 

369 

257 

551 

440 

846

734

3 × 10

1.8 

1.8 

1.8 

18.7 

21.9 

24.7 

533 

347 

745 

560 

1081

895

3 × 16

1.8 

1.8 

1.8 

20.8 

24.0 

26.8 

733 

440 

969 

675 

1340

1047

3 × 25

1.8 

1.8 

1.8 

23.6 

26.8 

30.3 

1056 

591 

1322 

856 

1916

1451

3 × 35

1.8 

1.8 

1.8 

25.8 

29.0 

32.5 

1357 

725 

1647 

1014 

2292

1659

3 × 50

1.8 

1.9 

2.0 

29.7 

33.1 

36.8 

1820 

972 

2167 

1319 

2914

2066

3 × 70

1.9 

2.0 

2.1 

28.9 

32.3 

37.2 

2336 

1071 

2673 

1408 

3668

2403

3 × 95

2.1 

2.2 

2.2 

33.1 

37.7 

41.2 

3172 

1422 

3894 

2145 

4638

2889

3 × 120

2.2 

2.3 

2.3 

35.7 

40.3 

43.8 

3908 

1702 

4684 

2477 

5490

3283

3 × 150

2.3 

2.4 

2.5 

39.3 

43.9 

49.0 

4808 

2090 

5658 

2940 

6992

4274

3 × 185

2.5 

2.6 

2.7 

43.3 

49.1 

53.0 

5989 

2558 

7039 

3608 

8400

4969

3 × 240

2.7 

2.8 

2.9 

48.5 

54.3 

58.6 

7711 

3244 

8879 

4412 

10443

5976

3 × 300

2.8 

2.9 

3.1 

61.9 

67.7 

72.2 

10165 

4542 

11644 

6020 

13695

8071

3 × 400

3.1 

3.2 

3.4 

69.9 

75.7 

81.5 

13037 

5879 

14697 

7539 

17861

10703

 

Four-Core Cable Structure Weight

Cable 
Model

Number of cores × Cross-section 
mm 2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

4 × 1.5

1.8 

1.8 

1.8 

12.8 

16.0 

17.9 

201 

350 

470

4 × 2.5

1.8 

1.8 

1.8 

13.7 

16.9 

18.8 

251 

191 

409 

349 

540

480

4×4

1.8 

1.8 

1.8 

15.7 

18.9 

21.7 

351 

254 

532 

435 

817

720

4 × 6

1.8 

1.8 

1.8 

17.1 

20.3 

23.1 

454 

305 

649 

501 

965

816

4 × 10

1.8 

1.8 

1.8 

20.3 

23.5 

26.3 

665 

417 

895 

647 

1259

1011

4 × 16

1.8 

1.8 

1.8 

22.7 

25.9 

29.4 

927 

536 

1183 

792 

1750

1359

4 × 25

1.8 

1.8 

1.8 

25.8 

29.0 

32.5 

1348 

727 

1637 

1016 

2280

1660

4 × 35

1.8 

1.8 

1.9 

28.2 

31.4 

35.1 

1739 

895 

2055 

1211 

2763

1920

4 × 50

1.9 

2.0 

2.1 

32.8 

36.2 

41.1 

2357 

1226 

2739 

1608 

3851

2721

4 × 70

2.0 

2.1 

2.2 

30.3 

34.9 

38.6 

3036 

1350 

3701 

2014 

4398

2712

4 × 95

2.2 

2.3 

2.4 

35.1 

39.7 

44.4 

4139 

1807 

4902 

2569 

6057

3724

4 × 120

2.3 

2.4 

2.5 

37.7 

42.3 

47.4 

5100 

2158 

5916 

2974 

7189

4247

4 × 150

2.5 

2.6 

2.7 

41.5 

47.3 

51.2 

6293 

2669 

7301 

3677 

8607

4983

4 × 185

2.6 

2.7 

2.9 

45.9 

51.7 

56.2 

7832 

3258 

8941 

4367 

10442

5868

4 × 240

2.9 

3.0 

3.1 

51.7 

57.5 

61.8 

10121 

4165 

11359 

5403 

12989

7033

4 × 300

3.1 

3.2 

3.3 

69.1 

74.9 

79.2 

13351 

5852 

14992 

7494 

17219

9721

4 × 400

3.4 

3.5 

3.6 

77.9 

83.7 

89.7 

17106 

7562 

18947 

9403 

22468

12923

 

Five-core cable structure weight

Cable 
Model

Number of cores × Cross-section 
mm 2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

5 × 1.5

1.8 

1.8 

1.8 

13.6 

16.8 

18.7 

233 

390 

517

5 × 2.5

1.8 

1.8 

1.8 

14.7 

17.9 

19.8 

295 

220 

465 

389 

601

525

5 × 4

1.8 

1.8 

1.8 

16.8 

20.0 

22.8 

416 

294 

608 

486 

915

793

5 × 6

1.8 

1.8 

1.8 

18.5 

21.7 

24.5 

545 

359 

756 

570 

1091

905

5 × 10

1.8 

1.8 

1.8 

22.0 

25.2 

28.7 

802 

493 

1051 

742 

1606

1297

5 × 16

1.8 

1.8 

1.8 

24.7 

27.9 

31.4 

1127 

638 

1405 

916 

2022

1533

5 × 25

1.8 

1.8 

1.9 

28.2 

31.4 

35.1 

1650 

874 

1966 

1190 

2673

1897

5 × 35

1.9 

1.9 

2.0 

31.1 

34.3 

38.8 

2151 

1097 

2498 

1443 

3516

2461

5 × 50

2.0 

2.1 

2.2 

36.1 

39.5 

44.4 

2914 

1500 

3332 

1919 

4553

3140

5 × 70

2.2 

2.2 

2.3 

40.9 

45.3 

49.0 

4060 

1952 

4925 

2817 

5886

3778

5 × 95

2.3 

2.4 

2.5 

46.2 

50.8 

55.9 

5456 

2541 

6453 

3537 

8056

5141

5 × 120

2.5 

2.6 

2.7 

50.6 

56.4 

60.3 

6755 

3078 

7976 

4299 

9548

5871

5 × 150

2.6 

2.8 

2.9 

56.0 

62.0 

66.3 

8317 

3787 

9691 

5161 

11508

6978

5 × 185

2.8 

2.9 

3.0 

62.3 

68.1 

72.4 

10372 

4654 

11860 

6142 

13861

8142

5 × 240

3.1 

3.2 

3.3 

69.7 

75.5 

81.1 

13353 

5908 

15009 

7564 

18127

10682

5 × 300

3.3 

3.4 

3.6 

76.5 

82.3 

88.5 

16596 

7223 

18407 

9034 

21916

12543

5 × 400

3.6 

3.8 

3.9 

86.3 

93.5 

98.3 

21268 

9337 

24217 

12286 

27246

15315

 

Weight of the 3+1-core cable structure

Cable 
Model

Number of cores × Cross-section 
mm 2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

3 × 2.5 + 1 × 1.5

1.8 

1.8 

1.8 

13.5 

16.7 

18.6 

239 

395 

523

3 × 4 + 1 × 2.5

1.8 

1.8 

1.8 

15.2 

18.4 

21.2 

326 

238 

501 

413 

779

691

3×6 + 1×4

1.8 

1.8 

1.8 

16.8 

20.0 

22.8 

429 

293 

621 

485 

929

793

3 × 10 + 1 × 6

1.8 

1.8 

1.8 

19.5 

22.7 

25.5 

611 

388 

833 

610 

1182

959

3 × 16 + 1 × 10

1.8 

1.8 

1.8 

22.1 

25.3 

28.8 

861 

506 

1110 

755 

1665

1310

3 × 25 + 1 × 16

1.8 

1.8 

1.8 

25.0 

28.2 

31.7 

1241 

677 

1522 

958 

2138

1575

3 × 35 + 1 × 16

1.8 

1.8 

1.9 

26.9 

30.1 

33.8 

1547 

817 

1849 

1118 

2533

1802

3 × 35 + 1 × 25

1.8 

1.8 

1.9 

27.6 

30.8 

34.5 

1709 

921 

2018 

1230 

2704

1916

3 × 50 + 1 × 25

1.9 

1.9 

2.0 

31.1 

34.3 

38.8 

2164 

1160 

2510 

1507 

3517

2514

3 × 70 + 1 × 35

2.0 

2.0 

2.1 

30.3 

33.5 

38.4 

2742 

1266 

3079 

1603 

4092

2616

3 × 95 + 1 × 50

2.1 

2.2 

2.3 

34.9 

39.5 

43.2 

3734 

1702 

4495 

2463 

5302

3270

3 × 120 + 1 × 70

2.2 

2.3 

2.5 

37.5 

42.1 

47.4 

4638 

2010 

5452 

2824 

6751

4123

3 × 150 + 1 × 70

2.4 

2.5 

2.6 

41.3 

45.9 

51.0 

5553 

2413 

6443 

3304 

7870

4730

3 × 185 + 1 × 95

2.5 

2.6 

2.7 

45.7 

51.5 

55.4 

6990 

2976 

8097 

4083 

9534

5520

3 × 240 + 1 × 120

2.7 

2.8 

2.9 

51.3 

57.1 

61.4 

9023 

3821 

10257 

5054 

11892

6690

3 × 300 + 1 × 150

2.9 

3.0 

3.1 

64.4 

70.2 

74.5 

11638 

5108 

13173 

6643 

15229

8699

3 × 400 + 1 × 240

3.2 

3.3 

3.5 

74.0 

79.8 

86.0 

15464 

6816 

17217 

8570 

20638

11991

 

Weight of the 3+2 Core Cable Structure

Cable 
Model

Number of cores × Cross-section 
mm 2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

3 × 2.5 + 2 × 1.5

1.8 

1.8 

1.8 

14.2 

17.4 

19.3 

269 

433 

568

3×4 + 2×2.5

1.8 

1.8 

1.8 

16.0 

19.2 

22.0 

368 

265 

551 

448 

844

741

3×6 + 2×4

1.8 

1.8 

1.8 

17.8 

21.0 

23.8 

493 

332 

695 

535 

1016

856

3 × 10 + 2 × 6

1.8 

1.8 

1.8 

20.6 

23.8 

27.3 

698 

438 

931 

671 

1447

1187

3 × 16 + 2 × 10

1.8 

1.8 

1.8 

23.6 

26.8 

30.3 

996 

579 

1262 

845 

1854

1437

3 × 25 + 2 × 16

1.8 

1.8 

1.8 

26.8 

30.0 

33.5 

1439 

778 

1740 

1079 

2408

1747

3 × 35 + 2 × 16

1.8 

1.8 

1.9 

28.4 

31.6 

35.3 

1728 

900 

2045 

1217 

2768

1940

3 × 35 + 2 × 25

1.8 

1.9 

2.0 

29.8 

33.2 

36.9 

1940 

997 

2289 

1346 

3037

2094

3 × 50 + 2 × 25

1.9 

2.0 

2.1 

32.9 

36.3 

41.2 

2397 

1238 

2780 

1621 

3917

2758

3 × 70 + 2 × 35

2.0 

2.1 

2.2 

30.9 

35.5 

39.2 

3117 

1430 

3795 

2108 

4509

2822

3 × 95 + 2 × 50

2.2 

2.3 

2.4 

35.7 

40.3 

45.0 

4244 

1929 

5020 

2705 

6201

3886

3 × 120 + 2 × 70

2.3 

2.4 

2.5 

38.5 

43.1 

48.2 

5388 

2338 

6221 

3171 

7516

4466

3 × 150 + 2 × 70

2.4 

2.6 

2.7 

42.5 

48.5 

52.4 

6329 

2767 

7385 

3823 

8706

5145

3 × 185 + 2 × 95

2.6 

2.7 

2.8 

47.3 

53.1 

57.4 

8052 

3455 

9193 

4596 

10720

6123

3 × 240 + 2 × 120

2.8 

2.9 

3.0 

52.7 

58.5 

62.8 

10273 

4336 

11537 

5599 

13220

7282

3 × 300 + 2 × 150

3.0 

3.1 

3.3 

68.3 

74.1 

78.6 

13222 

5786 

14847 

7411 

17074

9639

3 × 400 + 2 × 240

3.4 

3.5 

3.7 

79.7 

85.5 

91.7 

18068 

7931 

19951 

9814 

23606

13470

 

Four Plus One (4+1)-Core Cable Structure Weight

Cable 
Model

Number of cores × Cross-section 
mm 2

Nominal thickness of the outer jacket 
mm

Approximate outer diameter of the cable 
mm

Approximate weight of the cable 
kg/km

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

Non-armored

Steel tape armor

Steel wire armor

VV

VLV

VV22

VLV22

VV32

VLV32

VV 
VLV 
VV22
VLV22
VV32
VLV32

4 × 2.5 + 1 × 1.5

1.8 

1.8 

1.8 

14.5 

17.7 

19.6 

283 

450 

587

4×4 + 1×2.5

1.8 

1.8 

1.8 

16.4 

19.6 

22.4 

392 

280 

580 

467 

879

767

4×6 + 1×4

1.8 

1.8 

1.8 

18.1 

21.3 

24.1 

518 

345 

724 

551 

1052

879

4×10 + 1×6

1.8 

1.8 

1.8 

21.3 

24.5 

28.0 

750 

465 

991 

706 

1518

1234

4 × 16 + 1 × 10

1.8 

1.8 

1.8 

24.1 

27.3 

30.8 

1060 

607 

1331 

878 

1937

1484

4 × 25 + 1 × 16

1.8 

1.8 

1.9 

27.5 

30.7 

34.4 

1545 

826 

1853 

1134 

2548

1830

4 × 35 + 1 × 16

1.8 

1.9 

2.0 

29.6 

33.0 

36.7 

1930 

988 

2276 

1335 

3025

2084

4 × 35 + 1 × 25

1.8 

1.9 

2.0 

30.3 

33.7 

37.4 

2037 

1038 

2391 

1392 

3152

2153

4 × 50 + 1 × 25

2.0 

2.0 

2.1 

34.6 

37.8 

42.7 

2662 

1376 

3045 

1760 

4223

2938

4 × 70 + 1 × 35

2.1 

2.2 

2.3 

36.1 

40.7 

44.4 

3500 

1602 

4286 

2388 

5120

3223

4 × 95 + 1 × 50

2.3 

2.4 

2.5 

41.5 

46.1 

51.2 

4751 

2136 

5648 

3033 

7056

4441

4 × 120 + 1 × 70

2.4 

2.5 

2.6 

44.7 

50.5 

54.4 

5936 

2572 

7021 

3657 

8419

5055

4 × 150 + 1 × 70

2.5 

2.7 

2.8 

49.3 

55.3 

59.2 

7178 

3132 

8394 

4349 

9913

5868

4 × 185 + 1 × 95

2.7 

2.8 

2.9 

54.0 

59.8 

64.1 

8971 

3813 

10267 

5110 

11963

6805

4 × 240 + 1 × 120

2.9 

3.1 

3.2 

60.3 

66.3 

70.6 

11506 

4814 

12976 

6285 

14892

8201

4 × 300 + 1 × 150

3.2 

3.3 

3.4 

72.5 

78.3 

84.3 

14916 

6512 

16635 

8231 

19970

11566

4 × 400 + 1 × 240

3.5 

3.7 

3.8 

83.0 

90.2 

95.0 

19661 

8628 

22502 

11469 

25420

14386

 

Nominal Cross-Section 
mm2

Maximum DC resistance of the conductor at 20℃: Ω/km

Maximum AC resistance of the conductor at 70℃, Ω/km

Capacitor 
μF/km

The arrangement of cables

The

Mr. O

OOO

Copper

Aluminum

Copper

Aluminum

Inductance 
mH/km

Reactance 
Ω/cm

Inductance 
mH/km

Reactance 
Ω/cm

1.5

12.1

14.5 

0.578 

0.476 

1495 

0.522 

1640 

2.5

7.41

8.87 

0.689 

0.440 

1384 

0.487 

1529 

4

4.61

5.52 

0.696 

0.417 

1311 

0.464 

1457 

6

3.08

3.69 

0.817 

0.405 

1273 

0.451 

1418 

10

1.83

3.08 

2.19 

3.70 

1.11 

0.360 

1131 

0.406 

1276 

16

1.15

1.91 

1.38 

2.29 

1.35 

0.335 

1053 

0.381 

1199 

25

0.727 

1.20 

0.870 

1.44 

1.32 

0.327 

1029 

0.374 

1174 

35

0.524 

0.868 

0.627 

1.04 

1.51 

0.314 

986 

0.360 

1131 

50

0.387 

0.641 

0.464 

0.770 

1.55 

0.305 

958 

0.351 

1103 

70

0.268 

0.443 

0.321 

0.533 

1.80 

0.288 

903 

0.334 

1049 

95

0.193 

0.320 

0.232 

0.385 

1.81 

0.280 

881 

0.327 

1026 

120

0.153 

0.253 

0.184 

0.305 

2.02 

0.271 

850 

0.317 

995 

150

0.124 

0.206 

0.150 

0.249 

2.01 

0.270 

847 

0.316 

992 

185

0.0991 

0.164 

0.121 

0.198 

2.03 

0.266 

837 

0.313 

982 

240

0.0754 

0.125 

0.0930 

0.152 

2.08 

0.264 

829 

0.310 

974 

300

0.0601 

0.100 

0.0754 

0.122 

2.11 

0.261 

819 

0.307 

964 

400

0.0470 

0.0778 

0.0607 

0.0963 

2.22 

0.257 

806 

0.303 

951 

 

Model

VV, VLV, VV62, VLV62, VV72, VLV72

Arrangement method

The

Triangles (in contact with each other)

OOO

Flat type (adjacent spacing equals cable outer diameter)

OO

Installation method

In the air (ambient temperature 40°C)

In the soil (ambient temperature 25°C)

In the air (ambient temperature 40°C)

In the soil (ambient temperature 25°C)

Nominal Cross-Section 
mm2

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

1.5

19

27

24

29

2.5

25

19

36

27

31

24

38

30

4

33

26

47

35

41

32

49

39

6

41

34

58

46

52

42

61

50

10

57

44

78

58

72

55

83

64

16

76

59

100

76

95

73

105

83

25

98

76

130

98

120

96

135

105

35

115

90

155

115

150

115

160

125

50

145

110

185

140

180

140

195

150

70

180

140

225

170

230

175

240

185

95

225

175

270

205

280

215

285

220

120

260

200

310

235

325

250

325

250

150

300

230

350

265

375

290

365

285

185

354

270

395

300

430

335

415

320

240

410

320

455

350

510

395

480

375

300

475

370

515

395

585

455

545

425

400

555

440

585

455

690

540

625

490

 

Nominal Cross-Section 
mm2

In the air (ambient temperature 40°C)

In the soil (ambient temperature 25°C)

Two-core

More than three cores

Two-core

More than three cores

VV

VLV

VV

VLV

VV

VLV

VV

VLV

1.5

17

15

27

22

2.5

23

18

19

15

35

28

30

23

4

31

24

26

20

47

36

39

31

6

38

32

32

26

58

45

49

38

10

53

42

46

35

80

62

68

52

16

71

55

60

47

105

82

89

69

25

90

70

77

60

133

105

107

83

35

110

86

95

74

164

127

131

101

50

135

105

115

90

201

159

159

123

70

165

130

145

115

244

186

195

150

95

210

165

185

140

275

210

231

178

120

245

190

210

165

310

245

262

201

150

280

215

245

190

350

275

300

231

185

320

250

280

215

395

310

337

262

240

335

260

390

301

300

375

295

435

340

 

Environment

Different ambient temperatures (°C)

10

15

20

25

30

35

40

45

In the air

1.41 

1.35 

1.29 

1.22 

1.50 

1.08 

1.00 

0.91 

In the soil

1.15 

1.11 

1.05 

1.00 

0.94 

0.88 

 

Nominal Cross-Section 
mm2

Soil Thermal Resistance Coefficient (°C·m/W)

0.8 

1.0 

1.2 

1.5 

2.0 

35 and below

1.06 

1.00 

0.95 

0.89 

0.89 

50-120

1.08 

1.00 

0.94 

0.87 

0.87 

150–300

1.08 

1.00 

0.93 

0.86 

0.86 

400 and above

1.09 

1.00 

0.93 

0.85 

0.85 

 

 

Welcome to leave us your message or inquiry.

Our staff will contact you as soon as possible. If you require additional services, please feel free to call our service hotline: +86-18100332877

Recommended Products

We can customize special and specially shaped cables that meet or exceed national standards, tailored to the specific needs of our customers.

Online Consultation

Please enter your contact information, and we’ll get back to you as soon as possible!

Submit now